Beam bears on mass timber wall panel at pocket in wall. Beam is positively connected to wall with partially-threaded screws.

Purpose: Transfer of vertical load from steel beam to mass timber wall panel.

Design Notes

  • Capacity of connection is dependent on parallel-to-grain capacity of wall panel.
  • Increased capacity can be achieved with bearing plate below beam and/or bearing beam on full thickness of wall.
  • Connection is capable of transferring out-of-plane loads between wall panel and beam where no diaphragm is provided.
  • Allow adequate clearance in beam pocket for beam installation. • Addition of bearing plate may aid in fastener installation.
  • Constructability may depend on connection at opposite end of beam.
  • Constructability may be aided by providing a pocket that extends through the full thickness of the panel.
Class
Class 1
Load
Load High
Cost
Cost $
Const.
Constructability Advanced
Fire
Fire Rating II