Skip to content
Home > CAD & Revit - Mass Timber > Floor Panel Bears on Wall – Platform

Floor Panel Bears on Wall – Platform

Floor panel bears on wall panel below. Wall panel above bears on floor panel. A positive connection is made between panels with partially threaded screws.

Purpose: Transfer of vertical load from floor panel and wall panel above to wall panel below. Can also transfer in-plane and out-of-plane loads between the wall panels and floor panel.

Design Notes

  • Capacity of primary load path is controlled by perpendicular-to-grain bearing capacity of floor panel.
  • Screws provide load path for in-plane and out-of-plane loads.
  • Diagonal screws are used in this connection for positive attachment of upper wall. Care should be taken to not penetrate exterior face of the wall panel.
Class
Class 1
Load
Load Medium
Cost
Cost $
Const.
Constructability Easy
Fire
Fire Rating II

Floor Panel Bears on Wall – Platform

Floor panel bears on wall panel below. Wall panel above bears on floor panel. A positive connection is made between panels with partially threaded screws.
02.C - Floor Panel Bears on Wall - Platform