Conduit/Pipe Penetration at CLT Roof Deck

Description: Penetration in CLT is provided either pre-cored or cored in place depending on size of penetration required.

Purpose: Roof penetration for conduit/pipe at CLT roof deck.

 

Design Notes

  • Fire caulk penetration if rated roof.
  • Boot flashing and roof membrane transitions.

Acoustics:

  • 3PLY CLT = IIC 22 & STC 38 5 PLY CLT = IIC 25 & STC 41 (Rigid board and roofing membrane not included).

Fire:

  • Non-rated 3-ply CLT 1 1/2-hr rating possible: 5-ply CLT Design No. L901 Would require adding a topping under the rigid insulation.
Const.
Constructability Easy
Fire
Fire Rated Up To 1-1/2 Hours

Conduit/Pipe Penetration at CLT Roof Deck

Penetration in CLT is provided either pre-cored or cored in place depending on size of penetration required.
18-3-CONDUIT-CLT-ROOF-PENETRATION-AT-CLT-ROOF-DECK