Skip to content
Home > CAD & Revit - Mass Timber > Beam Bears on Mass Timber Wall Panel at Pocket

Beam Bears on Mass Timber Wall Panel at Pocket

Beam bears on mass timber wall panel at pocket in wall. Beam is connected to wall panel with partially-threaded screws.

Purpose: Transfer of vertical load from beam to mass timber wall panel. Can also transfer out-of-plane loads from the wall panel to the beam.

Design Notes

  • Capacity of connection is dependent on perpendicular-to-grain capacity of the beam.
  • Screws and bracket provide load path for in-plane and out-of-plane loads.
  • Screws can be installed diagonally from wall panel into beam (shown) or vertically from top of beam into wall panel.
  • Deck not shown for clarity. Beam may require bracing for lateral-torsional buckling.
Class
Class 1
Load
Load High
Cost
Cost $
Const.
Constructability Moderate
Fire
Fire Rating II

Beam Bears on Mass Timber Wall Panel at Pocket

Beam bears on mass timber wall panel at pocket in wall. Beam is connected to wall panel with partially-threaded screws.
03.C - Beam Bears on Mass Timber Wall Panel at Pocket