Skip to content
Home > CAD & Revit - Mass Timber > Typical Interior Demising Wall

Typical Interior Demising Wall

Description: Two layers of gypsum both sides; 2 1/2″-deep leg track at head for floor movement; lag screws used at underside of CLT; powder actuated fastener for attachment to topping.

Purpose: Typical interior demising wall mounted to CLT floor above and topping below.

 

Design Notes

  • One layer of gypsum could be substituted for resilient channel to improve STC rating.
  • Provide batt insulation in the cavity.

Acoustics:

  • 5/8″ Type X, one layer one side 3 1/2″ – 4″ batt (STC 50) 5/8″ one layer side one, two layers side two, 5/8″ Type X, 3 1/2″ – 4″ batt (STC 55) 5/8″ Type X, two layers each side 3 1/2″ – 4″ batt (STC).

Fire:

  • Non-rated 3-ply CLT 1 1/2-hr rating possible: 5-ply CLT Design No. L901.
Const.
Constructability Easy
Fire
Fire Rated Up To 1-1/2 Hours

Typical Interior Demising Wall

Two layers of gypsum both sides; 2 1/2"-deep leg track at head for floor movement; lag screws used at underside of CLT; powder actuated fastener for attachment to topping.